Por favor, use este identificador para citar o enlazar este ítem:
http://repositorio.pediatria.gob.mx:8180/handle/20.500.12103/2243
Título : | A reliable method of liquid chromatographyfor the quantification of acetaminophen andidentification of its toxic metaboliteN-acetyl-p-benzoquinoneimine for applicationin pediatric studies |
Creador: | Flores Pérez, Carmen |
Nivel de acceso: | Open access |
Palabras clave : | Acetaminofeno - sangre Adolescente Benzoquinonas - sangre Niño Niño, Preescolar Cromatografía, Líquido de Alta Presión Cromatografía, Reverse-Phase - métodos Monitoreo de medicamentos - métodos Estabilidad farmacológica Mujer Humanos Imines - sangre Infante Hombre Reproducibilidad de Resultados Sensibilidad y especificidad Acetaminophen - blood Adolescent Benzoquinones - blood Child Child, Preschool Chromatography, High Pressure Liquid Chromatography, Reverse-Phase - methods Drug Monitoring - methods Drug Stability Female Humans Imines - blood Infant Male Reproducibility of Results Sensitivity and Specificity Paracetamol N-acetil benzoquinoneimine HPLC Población pediátrica Acetaminophen N-acetyl benzoquinoneimine HPLC Pediatric population |
Descripción : | "El objetivo del presente estudio fue desarrollar un método simple, selectivo y confiable para cuantificar acetaminofén y su metabolito tóxico N-acetil-p-benzoquinoneimina (NAPQI) para estudios pediátricos utilizando muestras de plasma de 100 mL, por fase inversa
HPLC y detección UV. El ensayo se realizó usando una columna C18 y una elución isocrática con agua-metanol-
Ácido fórmico (70: 30: 0,15; v / v / v) como fase móvil. La linealidad del método se ensayó en el intervalo de 1-30 mg / ml para
Acetaminofén y 10-200 mg / mL para NAPQI, con un coeficiente de correlación r = 0.999 para ambos compuestos, y entre
Coeficientes de variación intra-día inferiores al 13%. Varios fármacos comúnmente administrados se analizaron por selectividad y
No se observó ninguna interferencia con las determinaciones. Los límites de detección y cuantificación de acetaminofén y NAPQI
Fueron 0,1 y 1 mg / ml, y 0,1 y 10 mg / ml respectivamente. El presente método puede usarse para monitorizar los niveles de acetaminofeno
Utilizando muestras de plasma de 100 ml, lo que puede ser útil cuando se necesitan analizar muestras muy pequeñas, como en la determinación farmacocinética o la monitorización de fármacos en plasma en niños. Este ensayo también es capaz de detectar la NAPQI para la monitorización de fármacos en pacientes diagnosticados con intoxicación por acetaminofén. Copyright © 2010 John Wiley & Sons, Ltd. " The aim of the present study was to develop a simple, selective and reliable method to quantify acetaminophen and its toxic metabolite N-acetyl-p-benzoquinoneimine (NAPQI) for pediatric studies using 100 mL plasma samples, by reversephase HPLC and UV detection. The assay was performed using a C18 column and an isocratic elution with water–methanol– formic acid (70:30:0.15; v/v/v) as mobile phase. Linearity of the method was assayed in the range of 1–30 mg/mL for acetaminophen and 10–200 mg/mL for NAPQI, with a correlation coefficient r = 0.999 for both compounds, and inter- and intra-day coefficients of variation of less than 13%. Several commonly co-administered drugs were analyzed for selectivity and no interference with the determinations was observed. The detection and quantification limits for acetaminophen and NAPQI were 0.1 and 1 mg/mL, and 0.1 and 10 mg/mL respectively. The present method can be used to monitor acetaminophen levels using 100 mL plasma samples, which may be helpful when very small samples need to be analyzed, as in pharmacokinetics determination or drug monitoring in plasma in children. This assay is also able to detect the NAPQI for drug monitoring in patients diagnosed with acetaminophen intoxication. Copyright © 2010 John Wiley & Sons, Ltd. |
Colaborador(es) u otros Autores: | Chávez Pacheco Juan Luis Ramírez Mendiola Blanca Alemón Medina Radamés García Álvarez Raquel Juárez Olguín Hugo Flores Pérez Janett |
Fecha de publicación : | 2011 |
Tipo de publicación: | Artículo |
Formato: | |
Identificador del Recurso : | 10.1002/bmc.1511 |
Fuente: | Biomed Chromatogr 25(7):760-766 |
URI : | http://repositorio.pediatria.gob.mx:8180/handle/20.500.12103/2243 |
Idioma: | eng |
Aparece en las colecciones: | Artículos |
Ficheros en este ítem:
No hay ficheros asociados a este ítem.
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.