Título : Incidencia de colonización de cateter epidural por via caudal lumbar y torácica en el Instituto Nacional de Pediatria
Incidence of epidural catheter colonization by lumbar and thoracic caudal at the National Institute of Pediatrics
Creador: Hernández Rivera, Juana Olivia
Nivel de acceso: Open access
Palabras clave : Anestesia epidural - Recién nacido
Epidural Anesthesia - Newborn
catéter peridural
contaminación
cateter peridural
contamination
Descripción : En la actualidad dentro del plan anestésico se debe de considerar el manejo de analgesia postquirurgica recientemente se ha utilizado el bloqueo peridural por diferentes vías anatomicas sin embargo hay reportes que refieren la presencia de contaminación de dichos cateteres MATERIAL Y METODOS:Se realizó un estudio de cohorte prospectivo y longitudinal en pacientes, del Instituto Nacional de Pediatría durante el periodo del 1 de Septiembre del 2004 al 30 de Octubre del 2005 para conocer la incidencia de colonización de catéteres por vía caudal, lumbar y torácica en el grupo de neonatos y hasta los 18 años de edad en los cuales se incluyeron aquellos pacientes que fue factible el manejo intraoperatorio y postquirúrgico con anestesia regional peridurai.Se excluyeron a los pacientes con alteraciones de la coagulación, infección en el sitio de puncióny no aceptación del padre o tutor. RESULTADOS : se estudiaron un total de 204 pacientes divididos en tres grupos de 64 ( torácico, lumbar y caudal) 40.7% del sexo femenino y 59.3% del sexo masculino, la edad media fue de 9.3 años con un peso de 33.08 Un total de 187 cateteres fueron negativos y unicamente 17 cateteres fueron positivos lo que equivale a un 8.3 % el tiempo medio de permanencia del cateter fue de 51.18 hrs con una p menor a 0.05 Asi mismo se clasificó el lugar físico donde se encontraban los pacientes en áreas de mayor o menor riesgo siendo estadísticamente significativo. El tipo de cateter que se utilizó fue clasificado en cateter con filtro antibacterial y sin filtro, observando que en aquellos pacientes que contenían filtro se contaminaban menos siendo estadísticamente significativos. CONCLUSIONES: podemos concluir por lo tanto que las horas de estancia del cateter, las areas de mayor contaminación y el uso de filtro antibacterial influyeron importantemente en la presencia de contaminación de nuestros catéteres y que contrario a lo que nosotros creíamos la localización del cateter no tubo tanta relevancia.
At the present time within the anesthetic plan the handling of postquirurgica analgesia is due to consider recently has been used the blockade peridural by different vias anatomías nevertheless are reports that refer the presence of contaminación of said cateteres MATERIAL ANO METODOS: was made a prospectivo study of cohorte and longitudinal in patients, of the Nationallnstitute of Pediatría during the period of the 1 of September from the 2004 to the 30 of October of the 2005 to know the incidence colonization of catheters by route of great volume, lumbar and toracica in the group of neoborn and until the 18 years of age in which those patients included themselves who were feasible the intraoperating handling and postquirurgico with regional anesthesia peridurai.Se excluded the patients with alterations of the coagulation, infection in the punción site, and nonacceptance of the father or tutor. RESUL TS: a total of 204 patients divided in three groups of 64 (toracico, lumbar and of great volume) 40,7% of feminine sex studied and 59,3% of masculine sex, the average age was of 9,3 years with a weight of 33.08 A 17 total of 187 cateteres was negative and cateteres were only positive what hrs with one is equivalent to 8,3 % the average time of 50 permanence of cateter was of p smaller to 0.05 The fisico place where were estadísticamente the patients in areas of greater or smaller risk being significant. The type of cateter that 1 am used was classified, in cateter with antibacterial filter and without filter observing that in those patients who contenían filter was contaminated less estadísticamente being significant. CONCLUSIONS: we can conclude therefore that the hours of stay of cateter, the greater areas of contaminación and the use of antibacterial filter importantly influenced in the presence of contaminación of ours cateteres and that in opposition to which we localización of cateter nontube as much relevance.
Colaborador(es) u otros Autores: Castillo Peralta Luz Antonia
Fecha de publicación : 2006
Tipo de publicación: Otros
Formato: pdf
URI : http://repositorio.pediatria.gob.mx:8180/handle/20.500.12103/761
Idioma: spa
Aparece en las colecciones: Tesis

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Tesis2006_55.pdf1.23 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.